Skip to content
CRCST Prep

Free tool · CRCST exam topic

CRCST practice test: Sterilization Process

10 exam-style questions on the Sterilization Process section of HSPA’s content outline, 21% of the exam. Answer each one to see the explanation; your score appears at the end.

10 questions · about 12 minutes. Pick an answer to see whether you’re right and why.

  1. Question 1 of 10According to CDC, what is the minimum exposure time for wrapped instruments in a gravity displacement steam sterilizer at 250°F (121°C)?
    Show answer

    Answer: D. 30 minutes

    CDC Table 7 lists 30 minutes at 121°C for wrapped instruments in a gravity displacement sterilizer (15 minutes at 132°C), with 15–30 minutes of drying.

  2. Question 2 of 10How often does CDC say an air-removal (Bowie-Dick) test must be run in a dynamic-air-removal steam sterilizer?
    Show answer

    Answer: C. Daily, in an empty chamber

    CDC: an air-removal test (Bowie-Dick test) must be performed daily in an empty dynamic-air-removal sterilizer. It checks that air is removed, which a gravity sterilizer does not do with a vacuum.

  3. Question 3 of 10According to CDC, how often should steam sterilizers be monitored with biological indicators, at minimum?
    Show answer

    Answer: B. At least weekly, and with every load that contains implantable items

    CDC: monitor at least weekly with spores; daily use allows earlier discovery of malfunctions in busy sterilizers; and each load containing implantable objects should be monitored.

  4. Question 4 of 10A biological indicator from a steam load is positive. How does CDC’s guideline treat this?
    Show answer

    Answer: A. As a possible sterilizer malfunction: items processed since the last negative BI are considered nonsterile and retrieved if possible

    CDC’s conservative approach treats any positive spore test as a sterilizer malfunction. Items processed from the cycle with the last negative BI onward are considered nonsterile, retrieved if possible and reprocessed.

  5. Question 5 of 10Which packaging should not be used in a hydrogen peroxide gas plasma sterilizer?
    Show answer

    Answer: D. Cellulose-based materials such as paper-plastic pouches and linen

    Cellulose absorbs hydrogen peroxide and can cause the cycle to abort or fail. Use packaging the sterilizer manufacturer has validated for the cycle.

  6. Question 6 of 10A wrapped tray comes out of a steam cycle with visible moisture on the wrap. What should be done?
    Show answer

    Answer: C. Treat it as contaminated, do not release it, reprocess it and look for the cause

    Moisture can wick microorganisms through the packaging, so a wet pack is considered contaminated. Common causes include overloading, heavy sets, poor steam quality and improper loading.

  7. Question 7 of 10How should basins and other items that can hold water be positioned in a steam sterilizer load?
    Show answer

    Answer: B. On their sides or tilted so condensate drains away

    Items that hold water trap condensate and air, which leads to wet packs and poor steam contact. Tilting them lets condensate drain and steam circulate.

  8. Question 8 of 10Which of these is not one of the four parameters of steam sterilization named by CDC?
    Show answer

    Answer: A. Gas concentration

    CDC names four parameters of steam sterilization: steam, pressure, temperature and time. Gas concentration is a parameter of low-temperature methods such as ethylene oxide.

  9. Question 9 of 10A steam load has just been removed from the chamber. What should happen before the packs are handled?
    Show answer

    Answer: D. Leave them on the loading cart to cool in a low-traffic area away from air vents

    Warm packs can draw in moisture and contamination if handled or placed on cold surfaces. Letting the load cool undisturbed protects the sterile barrier.

  10. Question 10 of 10According to CDC, which items should not undergo flash (immediate-use) steam sterilization?
    Show answer

    Answer: C. Implantable devices

    CDC: flash sterilization should not be used for implanted devices, and not for convenience or as a substitute for enough instrument sets.

What this section of the exam covers

Sterilization Process is 21% of the CRCST exam. Steam, ethylene oxide, hydrogen peroxide and dry heat; loading, cycle parameters, Bowie-Dick tests, biological indicators and recalls.

More free CRCST practice tests

FAQ

How much of the CRCST exam is Sterilization Process?
21% in HSPA’s CRCST content outline (revised November 2023). It covers: steam, ethylene oxide, hydrogen peroxide and dry heat; loading, cycle parameters, Bowie-Dick tests, biological indicators and recalls.
Are these real CRCST exam questions?
No. They are original exam-style questions written for practice and matched to HSPA’s content outline. HSPA does not release live exam questions.
Where can I practice more of this domain?
The CRCST Prep app has 155 questions on Sterilization Process alone, and 901 in total, with explanations, flashcards and 150-question mock exams.

Sources

  1. HSPA. CRCST Exam Content Outline (revised November 2023)
  2. CDC. Guideline for Disinfection and Sterilization in Healthcare Facilities (2008)

Original practice questions, not actual CRCST exam items. CRCST is a certification of HSPA, which does not endorse these tests. Always follow your facility’s policies and each device’s instructions for use.

* Pass Guarantee Program terms